Spray cork & render comparison · ECOPROCORK®

Compare cork, render
and insulation systems.

Use this cork render comparison to explore how ECOPROCORK® SLICS™ compares with silicone, monocouche and sand-and-cement render. See the differences at a glance, then check the technical data for your project.

Completed house exterior showing a cork finish

Define the brief first

A new finish, thermal improvement—or both?

A decorative finish is not the same as a whole-wall insulation upgrade. Equally, an insulation system must still be detailed and finished appropriately for the building.

Existing condition

Understand the wall or roof, existing coatings, defects, exposure and any moisture problem before choosing a material.

Required outcome

Set out the appearance, thermal objective, available space, maintenance expectations and project constraints.

Installed specification

Compare preparation, components, thickness, detailing, application, evidence and written warranty terms.

The spray-cork advantage

More from a thin, cork-based finish.

SLICS™ brings cork’s thermal properties, flexibility and a coloured finish together in a thin coating. See where it differs from conventional render options.

Feature offeredNot offered as describedCheck product / build-up

On smaller screens, swipe the matrix sideways to compare every option.

Spray cork compared with common render finishes — read the exact product data below.
What mattersECOPROCORK®
Spray cork SLICS™Decoproyec® cork coating
Silicone
renderThin-coat system
Monocouche
renderThrough-coloured cement
Sand & cement
renderTraditional / premixed
Natural cork contentCork-based coatingRenewable cork ingredientNo cork aggregateNo cork aggregateNo cork aggregate
Thermal function of the finishThermal cork coatingArchived sheet λ: 0.050 W/m·K¹; historical lab mean: 0.0588. Current grade to confirm.Decorative topcoatInsulation is a separate layerDecorative renderNot a dedicated insulation layerBase renderNot a dedicated insulation layer
Low build-upApprox. 3 mm coating²On a suitable prepared surfaceThin topcoatPlus the required basecoatTypically 15–25 mmFinish and exposure dependentTypically 16–20 mmExternal render, before decoration
FlexibilityElastic coating34.6% elongation at break¹Flexible optionsCheck the selected systemCement-based renderMovement detailing mattersCement-based renderMovement detailing matters
Water-vapour permeabilityVapour permeable¹Vapour permeablewebersil TF exampleCheck specificationProduct and build-up dependentBreathable renderweberend OCR example
Colour in the finishColoured cork textureColoured finishThrough-colouredSeparate decorationPaint or decorative finish
Exterior weather protectionSpecified cork systemPreparation and detailing requiredWater-repellent finishWeather-resistant renderWeather-resistant render
Lichen & moss observationsReported project observationsCase studies do not establish a universal tested resistance rating; confirm the exposure, maintenance and selected specificationCheck specificationConfirm for the selected productCheck specificationConfirm for the selected productCheck specificationConfirm for the selected product

Thermal evidence update, 19 October 2026: AITEX 2013AN1713 reports 0.0588 W/(m·K), while the archived spray datasheet quotes 0.050. The annex thickness and resistance entries also need clarification. Neither is a confirmed current design value here. Read the figures, scope and original report. The complete wall or roof needs a project-specific calculation.

Why choose SLICS™? A cork-based, flexible finish with minimal added thickness—an option worth considering when refurbishing a suitable existing surface without a thick render build-up.

¹ Manufacturer-reported product properties, not whole-wall performance. A thin cork coating adds limited thermal resistance; it does not replace external or internal wall insulation or establish an energy-saving percentage. Flexibility does not make a coating crack-proof: existing cracks and defects must be repaired.

² Approximate coating thickness only; preparation, primers and any supporting layers depend on the project. All options require a sound, suitable substrate. Weather protection depends on the complete specification; the cork layer alone is not a roof waterproofing system. The coating contains cork, binder and other ingredients.

Specialist applications · SLICS-C & SLICS-M

Coastal protection or comfort aboard?
Choose the route for your project.

Bring the cork approach to two very different environments. SLICS-C focuses on coastal building refurbishment. SLICS-M focuses on internal insulation for boats and narrowboats. Compare the benefits, then explore the products, application and evidence for your project.

On smaller screens, swipe across the matrix to read every column.

SLICS-C and SLICS-M: choose by application
Your prioritySLICS-C · Coastal ProtectionSLICS-M · Marine Insulation
Where it belongsCoastal homes, hotels and other exposed building frontages.Suitable internal surfaces in boats and narrowboats, including assessed barge and houseboat conversions.
What you want to achieveRefresh coastal character and plan an appropriate exterior finish and care regime.Bring cork into the insulation design while working around interior space and structural details.
System approachAssessed wall, preparation and repairs, compatible supporting layers where needed, then specified sprayed cork.Assessed internal substrate, compatible preparation and primers, specified successive cork coats, coordinated insulation and lining.
Start your projectExplore the coastal systemExplore internal boat insulation

SLICS-C benefits matrix.

On smaller screens, swipe across the matrix to read every column.

SLICS-C Coastal Protection: benefits and project considerations
FeatureBenefit for your coastal propertyHow to specify it
Cork-based coloured finishRefresh the appearance and texture of an exposed frontage.Choose colour, texture and a representative sample area for the property.
Flexible application routesAssess options from a sound existing surface through to reinforced basecoat or cork-board insulation.Select the complete build-up for substrate condition, exposure and the thermal brief.
Coastal exposure consideredBring salt-laden air, rain exposure, repairs and maintenance into one specification.Use the scoped salt-spray evidence alongside the actual wall assessment and detailing.
Maintenance planned from the startConsider future access, inspection and upkeep before work begins.Agree care requirements and written product and installation warranty terms.
Products and practical skillsExplore spray cork products and equipment.Get trained at the ECOPROCORK Academy.

SLICS-M benefits matrix.

On smaller screens, swipe across the matrix to read every column.

SLICS-M Internal Boat Insulation: benefits and project considerations
FeatureBenefit inside your boat or narrowboatHow to specify it
Spray-applied coverageFollow accessible curves, panels and framing with less cutting and fitting around details.Confirm preparation, primer, trial-area adhesion and coverage before closing the lining.
Compact cork layerPreserve useful space around headroom, cupboards and services.Agree the installed dry thickness and additional insulation needed for the complete fit-out.
Comfort-led fit-outConsider cork within the insulation, moisture-control and acoustic-comfort design.Coordinate ventilation, heating, moisture sources, insulation and lining; quantify performance only with applicable evidence.
Successive-coat applicationBuild the cork layer through a controlled application sequence.Agree the selected product, coat thickness, drying conditions, access and inspection.
Equipment and training togetherExplore DECOPROYEC sprayed cork and CP19 equipment.Learn effective application at the Academy and discuss the specific vessel.

Get equipped. Get trained. Put cork to work.

Explore products and spray equipment, build practical application skills, then bring the right system to coastal properties or boat interiors.

Evidence follows the application. These are application routes, not interchangeable approvals. Historical salt-spray results concern tested specimens and do not establish service life, universal corrosion protection or immersion suitability. C-s1,d0 applies within the documented sprayed-cork test scope; it is not marine approval or classification of every complete lining. Obtain current grade-specific thermal data and assess the full wall or vessel build-up. A thin coating alone does not establish a U-value or guarantee condensation or acoustic outcomes. Read the datasheets, reports and evidence limits.

Check the exact specifications

Download the technical data sheets.

Check the figures, application conditions and limitations for the product you are considering. These render examples support the comparison; individual products within each category vary.

PDFs open in a new tab for viewing or downloading. The spray-cork PDF is the published V1 document; confirm the applicable revision and full SLICS™ specification with ECOPROCORK before use. The manufacturer’s online product data is marked updated 24 January 2026. If documents differ, request written clarification for your application.

Evidence before claims

Five questions for every quote.

Ask the same questions of every proposed system so that the comparison remains useful and fair.

Technical information
  1. What preparation and repairs are included?
  2. Which exact products, thicknesses and details are specified?
  3. What thermal, moisture and fire evidence applies to this build-up?
  4. Who will install it, and how will quality be recorded?
  5. What maintenance and written warranty terms apply?

Your next step

Bring us the building brief.

Share the property type, location, photographs and intended work. We can discuss the appropriate ECOPROCORK route and the evidence needed before a specification is agreed.

Sources and further reading

Manufacturer guidance explains the distinction between monocouche and silicone render systems and the components of an acrylic render system. The Energy Saving Trust explains internal and external solid-wall insulation. These references describe categories and examples; they do not certify an ECOPROCORK installation.

Guide reviewed October 2026. For ECOPROCORK product and system evidence, request the current documents for your proposed application.

Compare insulation routes as well as finishes

Internal insulation: compare the full lining and insulation build-up, room-space impact, services and junctions. Explore internal wall insulation.

External insulation: compare the insulation layer, fixings, reinforcement, finish and details at openings, roofs and plinths. Explore external wall insulation.

Thin cork treatments: consider their specified surface role and limited thermal resistance alongside space constraints. Read the thin-wall guide. A thin finish is not a like-for-like replacement for a thicker insulation layer.

Solid and traditional walls: compare exposure, existing finishes, drying and the proposed complete construction. Solid-wall options · Breathable insulation explained.

View the wall build-up diagrams to compare the layers in internal and external wall systems.

Use the Insulation & Retrofit hub for the full planning route. Compare quotes against the same thermal objective, required repairs, installed scope and evidence. Do not infer universal bill savings or mould prevention from a material description.